date well_id notes well_stickup_cm depth_to_water_cm
2016-07-08 1_S Replaced the data logger at 9:33 62.300000000000004 67
2016-07-08 10_S This well was partially pulled from the ground. I stuck it back in the hole and measured water depth the next day. 20.5 55
2016-07-08 11_S This well was partially pulled from the ground. I stuck it back in the hole and measured water depth the next day. 21.1 45.5
2016-07-08 12_S This well was partially pulled from the ground. I stuck it back in the hole and measured water depth the next day. 9.5 44.1
2016-07-08 13_S This well was partially pulled from the ground. I stuck it back in the hole and measured water depth the next day. 24 48.4
2016-07-08 14_S This well was pulled from the ground. I stuck it back in the hole and measured water depth the next day. Not enough water had flowed back into the well the following morning to be able to collect water with the bailer. pH and EC was measured by lowering the electrodes into the well. 14.1 93.2
2016-07-08 2_S Replaced the data logger at 9:53 44 71.7
2016-07-08 4_S Replaced the data logger at 10:42 29.2 44
2016-07-08 6_S This well was partially pulled up by a hooligan. I pushed it back so that the marker line (marking ground level) was once again flush with the ground and then measured the water depth at that time, as well as the following day. The difference was negligibile (initially 42.4/14/122) 14 42.4
2016-07-08 7_S This well was pulled from the ground. I stuck it back in the hole and measured water depth the next day. This is a lagg well, with saturated soils and standing water around it. The water level in the well seems to deep and may be a result of not having refilled sufficiently from the previous day. 19.399999999999999 55.8
2016-07-08 9_S This well was partially pulled from the ground. I stuck it back in the hole and measured water depth the next day. 26.3 73
2016-09-21 1_S Replaced data logger at 10:05 59 65
2016-09-21 14_S No water depth measurement this time (vandalism) NA NA
2016-09-21 15_S Rediscovered this trip 49.5 71.754999999999995
2016-09-21 2_S Pushed peat back down around base of well; Replaced data logger at 10:20 41.8 71.450199999999995
2016-09-21 4_S Replaced data logger at 10:43 29.8 41.274999999999999
2016-09-21 6_S Replaced yesterday (9/20) after vandalism; Some PVC shreds in the H2O sample; 1st measure of EC registered 119.6 23.4 81.915000000000006
2017-01-18 1_S Logger removed from well 1/17 13:22 to 1/18 10:20 and 1/18 13:10 to 13:13; Measurements done with english-unit tape and then converted to metric. 61.912500000000001 66.674999999999997
2017-01-18 4_S pH was 4.76 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 21.11375 21.59
2017-01-18 5_S pH was 4.15 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 38.417500000000004 41.592500000000001
2017-01-18 6_S pH was 4.53 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 21.907499999999999 36.353749999999998
2017-01-18 7_S pH was 4.55 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 22.463125000000002 17.383125
2017-01-18 8_S pH was 5.07 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 35.2425 48.895000000000003
2017-01-19 14_S Hidden beneath moss because of hooligans; Measurements done with english-unit tape and then converted to metric. 7.4612499999999997 27.305
2017-01-18 12_S pH was 4.74 when probe was not swirled; Measurements done with english-unit tape and then converted to metric. 3.81 2.9368750000000001
2017-01-18 15_S Remeasure total depth in the spring, may have been ice in the well; Measurements done with english-unit tape and then converted to metric. 48.577500000000001 59.848750000000003
2017-04-25 1_S Original measures were 4.91 pH and 15.64 EC; Remeasured after doing well 2 and noticed funky setting on meter 60.1 60.1
2017-04-25 7_S Standing water 19 14
2017-07-06 2_S 42.9 cm to line on well 44.8 78
2017-07-06 3_S lines redrawn 12.8 54
2017-07-06 4_S line redrawn 24 47
2017-07-06 5_S line redrawn 40.6 63.7
2017-07-06 6_S line redrawn 19.8 51.1
2017-07-06 7_S Lid appears to have been kicked off by elk, so the well was also loose in the hole; filled the gap around the well after measuring 21.9 30.5
2017-07-06 8_S 35.7 cm to line 36.5 75.400000000000006
2017-07-06 14_S line redrawn 6.2 43.4
2017-07-06 12_S line redrawn 3.2 33
2017-07-06 11_S line redrawn 9.6999999999999993 46.9
2017-07-06 10_S line redrawn 7 52.6
2017-07-06 9_S line redrawn 16.5 68.099999999999994
2017-07-06 13_S line redrawn 25.5 64.5
2017-07-06 15_S line redrawn 48.1 84.6
2017-08-29 1_S This well was dry, no sample was collected; Used top loop of string for the logger; Troll removed at 12:10 8/28 and replaced 9:09 8/29 NA DRY
2017-08-29 2_S Did not bail the suggested volume (ran out of H20); Collected 1/2 samples due to limited water; Measured EC & pH in between non-acid and acid samples; Troll removed at 12:15 8/28 and replaced 9:16 8/29 46.4 113.8
2017-08-29 4_S Troll removed at 12:48 8/28 and replaced 9:32 8/29 26.9 81.7
2017-08-29 7_S This well was dry, no sample was collected NA DRY
2017-08-29 8_S This well was dry, no sample was collected NA DRY
2017-08-29 14_S This well was in place, but someone/thing dug around it again and removed the cap. The stick-up was measured to the nearby ground (not the surface immediately surrounding it, because it had been dug out; Bailed the well dry, but did not get the calculated volume; 1/2 sample due to limited water, measured EC and pH before bottling 7.2 73
2017-08-29 12_S Stick up is 12.9 to current surface, but 4.4 to the line drawn on the pipe; Moss has either subsided or the well has been messed with. Bailed the well dry, but did not get the calculated volume 12.9 59
2017-08-29 11_S Bailed the well dry, but did not get the calculated volume 11.5 76.2
2017-08-29 10_S Bailed the well dry, but did not get the calculated volume 8.6999999999999993 57.8
2017-08-29 13_S 1/2 sample due to limited water, measured EC and pH before bottling 27 102.1
2018-01-18 1_S Used top loop in string for replacing TROLL 62.4 63.5
2018-01-18 4_S Original ec reading was 150+. Recalibrated and got the number here. 23.5 28.6
2018-01-18 5_S Disturbed slightly (very slightly angled); cap was off when we arrived; remeasured 1/18 but got very similar depth (44.0) 41.3 47.6
2018-01-18 7_S Cap was off when arrived 18.100000000000001 14.6
2018-01-18 14_S Cap was off (and missing) when arrived. This well is in a shallow concavity now, since all of the previous disturbance and subsidence. Stick up is only 6.1 cm to surrounding area, but 12.7 immediately next to the well. 12.7 25.2
2018-01-18 12_S Uneven surface around well, measured @ line 9.6999999999999993 6.6
2018-01-18 9_S Calibrated ec (1413), but was immediately 1480 when measured again. Many of these ec readings at WTC seem high. 16 54
2018-01-18 15_S Cap off when arrived, slightly pulled up. 48.8 64
2018-04-18 1_S Logger replaced 4/19 9:27 61.2 61.8
2018-04-18 2_S Logger replaced 4/19 9:37 43.7 54.8
2018-04-18 4_S Logger replaced 4/19 10:27 22.4 25.3
2018-04-18 7_S Water above surface 17.7 17
2018-04-18 14_S 5.8 cm to old line, nearly flush w/ surrounding surface 12.8 24.2
2018-04-18 12_S Measured on marked side. Only 2 cm to surrounding surface area (marked side is in depression). 9.5 9.1999999999999993
2019-04-09 1_S *Well had been disturbed when I arrived. It was pushed over and slightly pulled up. When I arrived, the top of the pipe was 56.5 cm directly above the water surface and 58 cm if following the side of the pipe, the stick up was 59.5 vertically and 61 cm if following the side of the pipe. I straightened the pipe & filled in around it and remeasured. Those numbers are presented in the Depth to Water and Stickup columns, but the numbers here should be used if checking/calibrating the data logger. Logger replaced at 14:17 60.5 60
2019-04-09 2_S Well had been disturbed. Pushed over at a slight angle. I straightened it slightly and filled in the gap that had been created at the base. Not enough to meaningfully impact the logger readings. Logger replaced at 14:19 43 52
2019-04-09 4_S Cap was off of shallow well when I arrived; Logger replaced at 9:30 on 4/10 25 23
2019-04-09 5_S Baro collected 11:34 and replaced at 9:35 on 4/10; Some peat removed around base of shallow well by hoodlums--I replaced it. 41.5 44.5
2019-04-09 6_S Shallow well was pulled up somewhat and excavated around the base. I filled in the hole at the base and measured the stickup to this new surface. 21 35
2019-04-09 7_S Well pulled up and on the ground when I arrived. I replaced it and measured new stickup value. 25.5 18
2019-04-09 14_S Cap was off when I arrived. I filled in the soil subsidence around this well. 9 23
2019-04-09 12_S Well was pulled up slightly when I arrived. I pused it back in before measuring. 9 14.5