Which process should be used?

Both processes have subgroup size 5, target 100, and specifications 90 to 110. The subgroup correction is c4=0.9400c_4=0.9400. Process A is centered. Process B is five units high but has one-third the within-process standard deviation. B is preferable for meeting the specifications and offers the greatest potential if its mean can be brought back to 100. A has the higher target-based capability index at the current settings. Source: Montgomery, 7th ed., p. 405, Table 8E.1.

Within-process variation and capability
Process Mean Sbar SD Cp Cpk Cpm
A 100 3 3.1915 1.0444 1.0444 1.0444
B 105 1 1.0638 3.1333 1.5667 0.6521
Capability by process
Capability of the measured process

For a sample of 30 parts, the mean is 97, the sample SD is 1.6, and the specifications are 90 to 100. The upper-side index determines Cpk. The entire approximate 95% confidence interval lies below 1. Source: Montgomery, 7th ed., p. 406 and equation 8.21, p. 371.

Point and interval estimates
Lower-side index Upper-side index Cpk 95% lower 95% upper
1.4583 0.625 0.625 0.4247 0.8253
Estimate and approximate 95% interval
9.1 · Molecular weight

Target 1,050, design SD 25, target shift 1 SD. Using k=0.5k=0.5 and h=5h=5 gives K=12.5K=12.5 and H=125H=125. The first upper alarm is observation 10 (C+=170.5C^+=170.5). The last zero before the alarm occurs at 7, suggesting a shift starting at 8. The moving-range estimate of SD is 34.43, about 38% above 25. The assumed SD looks low; the mean shift can inflate this retrospective estimate. Source: p. 444, Table 9E.1.

Tabular CUSUM through the first alarm
All observations · no reset after the first alarm
i Weight C+ C-
1 1045 0.0 0.0
2 1055 0.0 0.0
3 1037 0.0 0.5
4 1064 1.5 0.0
5 1095 34.0 0.0
6 1008 0.0 29.5
7 1050 0.0 17.0
8 1087 24.5 0.0
9 1125 87.0 0.0
10 1146 170.5 0.0
11 1139 247.0 0.0
12 1169 353.5 0.0
13 1151 442.0 0.0
14 1128 507.5 0.0
15 1238 683.0 0.0
16 1125 745.5 0.0
17 1163 846.0 0.0
18 1188 971.5 0.0
19 1146 1055.0 0.0
20 1167 1159.5 0.0
9.16 · Clinic waiting time

Given λ=0.1\lambda=0.1. Using L=2.7L=2.7 (Example 9.2, p. 435) and all 30 observations for the trial limits, z0=x‾=4.6457z_0=\bar x=4.6457 and σ̂=MR¯/1.128=3.8255\hat\sigma=\overline{MR}/1.128=3.8255. 0 of 30 EWMA values cross a limit. At observation 30 the raw wait is 36.99 and the smoothed value is 6.893, below the UCL of 7.013. The chart gives no mean-shift signal under these trial limits. The long final wait warrants review. Source: p. 446, data on p. 292, Table 6E.24.

EWMA with time-varying trial limits
EWMA plotting values
i Wait EWMA LCL UCL
1 2.49 4.430 3.613 5.679
2 3.39 4.326 3.256 6.035
3 7.41 4.634 3.024 6.268
4 2.88 4.459 2.857 6.434
5 0.76 4.089 2.733 6.558
6 1.32 3.812 2.638 6.653
7 7.05 4.136 2.565 6.727
8 1.37 3.859 2.507 6.784
9 6.17 4.090 2.461 6.830
10 5.12 4.193 2.425 6.867
11 1.34 3.908 2.396 6.896
12 0.50 3.567 2.373 6.919
13 4.35 3.646 2.354 6.937
14 1.67 3.448 2.339 6.952
15 1.63 3.266 2.327 6.965
16 4.88 3.428 2.317 6.974
17 15.19 4.604 2.309 6.982
18 0.67 4.210 2.303 6.988
19 4.14 4.203 2.298 6.994
20 2.16 3.999 2.294 6.998
21 1.14 3.713 2.290 7.001
22 2.66 3.608 2.288 7.004
23 4.67 3.714 2.285 7.006
24 1.54 3.497 2.284 7.008
25 5.06 3.653 2.282 7.009
26 3.40 3.628 2.281 7.010
27 1.39 3.404 2.280 7.011
28 1.11 3.175 2.279 7.012
29 6.92 3.549 2.279 7.013
30 36.99 6.893 2.278 7.013
15.5 · Type-B OC curve

Inspect 50 items. Accept when at most one is defective. For incoming fraction defective pp, Pa=P(D≤1)=(1−p)50+50p(1−p)49P_a=P(D\le1)=(1-p)^{50}+50p(1-p)^{49}. With 5% defective, the probability of acceptance is 0.2794. Source: p. 686.

Probability of lot acceptance
OC plotting values
Defective (%) P(accept)
0 1.0000
1 0.9106
2 0.7358
3 0.5553
4 0.4005
5 0.2794
6 0.1900
8 0.0827
10 0.0338
15 0.0029
20 0.0002
30 0.0000
15.16 · Two-stage acceptance plan

Inspect 50 items. Accept for 0–2 defectives, reject for 7 or more, and inspect 100 more for 3–6. After the second sample, accept if the combined count is at most 6. At 5% defective, the first-sample acceptance probability is 0.5405, final acceptance is 0.6159, and first-sample rejection is 0.0118. Source: p. 687.

Primary and supplementary OC curves
OC plotting values
Defective (%) Final accept First accept First reject
0 1.0000 1.0000 0.0000
1 0.9996 0.9862 0.0000
2 0.9847 0.9216 0.0001
3 0.9146 0.8108 0.0007
4 0.7799 0.6767 0.0036
5 0.6159 0.5405 0.0118
6 0.4607 0.4162 0.0289
8 0.2360 0.2260 0.1019
10 0.1132 0.1117 0.2298
15 0.0142 0.0142 0.6387
20 0.0013 0.0013 0.8966
30 0.0000 0.0000 0.9975
Second-stage contributions at 5% defective
First count P(first count) P(second count ≤ 6 − j) Contribution
3 0.219875 0.257839 0.056692
4 0.135975 0.118263 0.016081
5 0.065841 0.037081 0.002441
6 0.025990 0.005921 0.000154