| Group | Block | Go retained | No-Go retained | Rejected epochs |
|---|---|---|---|---|
| NPSU | Notification | 273.82 (4.57) | 107.94 (15.43) | 5.47 (4.56) |
| NPSU | Silence | 274.18 (6.16) | 103.82 (19.91) | 6.76 (8.44) |
| PSU | Notification | 271.12 (10.22) | 109.12 (6.36) | 11.29 (13.45) |
| PSU | Silence | 270.29 (7.23) | 106.65 (8.78) | 12.59 (12.38) |
Supplementary Material
This material provides supplementary analyses for a visual Go/No-Go study of 34 participants (17 with problematic smartphone use [PSU] and 17 without [NPSU]). The experimental design comprised a between-subjects factor, Group (PSU vs. NPSU), and a within-subjects factor, Block (Notification vs. Silence). The Notification block involved an active personal smartphone receiving scheduled WhatsApp messages and potentially incidental notifications; the Silence block involved the same device switched off. Accordingly, Block contrasts reflect smartphone availability and notification exposure jointly, not the isolated effect of individual notifications. Event-related potentials (ERPs) were time-locked to task stimuli and averaged separately for correct Go and No-Go trials.
S1. EEG quality control
The final EEG sample comprised 34 participants, with both experimental blocks available for each participant. The number of retained correct-trial epochs and rejected epochs was summarized by group and block (Supplementary Table 1). Across both blocks, participants contributed a mean of 758.5 retained epochs (SD = 31.7; range: 639–795). The minimum number of retained correct No-Go epochs was 68 in the Notification block and 38 in the Silence block. All participants in the final sample were retained for the ERP analyses; data quality and the sensitivity analysis excluding the participant with the lowest No-Go trial count are reported in the main manuscript.
Note. Values are mean (SD) per participant (n = 17 per group). Go and No-Go counts refer to retained correct trials; rejected epochs are reported as a separate count.
The rejection percentages in the manuscript were calculated from the number of rejected epochs divided by the sum of retained correct-trial and rejected epochs. The Notification block contained 12,954 retained and 285 rejected epochs (2.15%); the Silence block contained 12,834 retained and 329 rejected epochs (2.50%). Overall, 614 of 26,402 epochs were rejected (2.33%). These percentages do not use the total number of presented experimental trials as the denominator.
S2. Supplementary behavioral analyses
Individual behavioral performance and complete mixed-design ANOVA results complement Table 1 of the main article. Each participant contributed one observation per experimental block.
S2.1. Mixed-design ANOVA
| Measure | Effect | df1 | df2 | F | p | Generalized eta-squared | Partial eta-squared | Adjusted p |
|---|---|---|---|---|---|---|---|---|
| RT | Group | 1 | 32 | 0.188 | 0.668 | 0.0054 | 0.0058 | 1.000 |
| RT | Block | 1 | 32 | 0.361 | 0.552 | 0.0008 | 0.0111 | 1.000 |
| RT | Group × Block | 1 | 32 | 0.383 | 0.541 | 0.0008 | 0.0118 | 1.000 |
| FA rate | Group | 1 | 32 | 0.706 | 0.407 | 0.0199 | 0.0216 | 1.000 |
| FA rate | Block | 1 | 32 | 2.512 | 0.123 | 0.0063 | 0.0728 | 0.491 |
| FA rate | Group × Block | 1 | 32 | 0.578 | 0.453 | 0.0014 | 0.0177 | 1.000 |
| Go accuracy | Group | 1 | 32 | 0.837 | 0.367 | 0.0207 | 0.0255 | 1.000 |
| Go accuracy | Block | 1 | 32 | 0.201 | 0.657 | 0.0012 | 0.0062 | 1.000 |
| Go accuracy | Group × Block | 1 | 32 | 1.356 | 0.253 | 0.0080 | 0.0407 | 1.000 |
| d′ | Group | 1 | 32 | 0.293 | 0.592 | 0.0080 | 0.0091 | 1.000 |
| d′ | Block | 1 | 32 | 1.954 | 0.172 | 0.0069 | 0.0575 | 0.687 |
| d′ | Group × Block | 1 | 32 | 1.067 | 0.309 | 0.0038 | 0.0323 | 1.000 |
Note. Adjusted p values correspond to Bonferroni adjustment across the four behavioral measures separately for each effect, as reflected in the exported results. None of the 12 effects reached the nominal .05 threshold (all unadjusted p ≥ .123). Generalized eta squared and partial eta squared are reported separately.
S2.2. Assessment of assumptions
| Measure | PSU_Notification | PSU_Silence | NPSU_Notification | NPSU_Silence |
|---|---|---|---|---|
| RT | 0.217 | 0.890 | 0.086 | 0.022 |
| FA rate | 0.091 | < .001 | < .001 | < .001 |
| Go accuracy | < .001 | 0.010 | < .001 | < .001 |
| d′ | 0.123 | 0.093 | 0.013 | 0.002 |
| Measure | Block | F | p |
|---|---|---|---|
| RT | Notification | 6.472 | 0.016 |
| RT | Silence | 5.954 | 0.020 |
| FA rate | Notification | 0.646 | 0.427 |
| FA rate | Silence | 1.348 | 0.254 |
| Go accuracy | Notification | 2.376 | 0.133 |
| Go accuracy | Silence | 0.475 | 0.495 |
| d′ | Notification | 0.394 | 0.535 |
| d′ | Silence | 0.755 | 0.391 |
Note. Shapiro–Wilk tests identified departures from normality at the nominal .05 threshold in at least one group-by-block cell for each behavioral measure. Levene tests indicated unequal group variances for RT in both blocks (p = .016 and .020). These diagnostics concern the cell-level distributions and block-specific variances; they do not directly assess model residuals or the distribution of paired difference scores.
S2.3. Complementary nonparametric analyses
| Measure | Effect | Statistic | p |
|---|---|---|---|
| RT | Block | 296.0 | 0.986 |
| RT | Group | 162.0 | 0.558 |
| RT | Group × Block | 121.0 | 0.428 |
| FA rate | Block | 157.0 | 0.194 |
| FA rate | Group | 152.5 | 0.796 |
| FA rate | Group × Block | 170.0 | 0.388 |
| Go accuracy | Block | 108.0 | 0.804 |
| Go accuracy | Group | 141.5 | 0.930 |
| Go accuracy | Group × Block | 183.0 | 0.175 |
| d′ | Block | 320.0 | 0.161 |
| d′ | Group | 130.0 | 0.630 |
| d′ | Group × Block | 167.0 | 0.448 |
Note. The complementary rank-based tests are reported for all four behavioral measures and all three effects. Reported p values are unadjusted; none reached the nominal .05 threshold. These tests are not treated as exact nonparametric equivalents of the mixed-design ANOVA.
S3. Supplementary ERP waveforms
This section complements the No-Go component figures in the main article by presenting whole-scalp waveforms and electrode-level Go responses. PSU = problematic smartphone use; NPSU = non-problematic smartphone use (n = 17 per group). ERP = event-related potential; ROI = region of interest; LP = late positivity.
S3.1. Whole-scalp grand averages
S3.2. Go waveforms at ROI electrodes
The figures display the grand-average waveforms at the electrodes used to quantify each component in correct Go trials. The N2 and P3 measurement windows were centered on peaks identified from the combined grand average (groups and blocks collapsed; ±20 ms). The LP window was fixed at 600–789 ms. Quantification used the original unsmoothed waveforms. The corresponding No-Go figures are presented in the main article.
S4. Supplementary scalp topographies
The following scalp voltage distributions complement the No-Go topographies in the main article. Maps are descriptive, not statistical significance maps. Within each component, the four group-by-block panels use a shared color scale; symmetric limits were set using the empirical 95th-percentile cutoff (nearest rank) of absolute electrode amplitudes across the four maps, so extreme values may be saturated.
# S5. Supplementary ROI-based statistical analyses
This section provides extended descriptive statistics, model diagnostics, and complementary rank-based tests for the ROI-based ERP analyses reported in the main manuscript. The complete factorial ANOVA and follow-up contrasts are reported in the main manuscript. Amplitudes are expressed in microvolts (µV).
S5.1. Extended descriptive statistics
| Trial | Component | Group | Block | n | M (SD) | Median [Q1, Q3] | Min–Max | Flags |
|---|---|---|---|---|---|---|---|---|
| Go | N2 | NPSU | Silence | 17 | -2.83 (1.83) | -2.65 [-4.54, -1.70] | -5.63 to 0.25 | 0 |
| Go | N2 | NPSU | Notification | 17 | -3.17 (2.17) | -2.88 [-4.54, -1.57] | -8.76 to -0.39 | 0 |
| Go | N2 | PSU | Silence | 17 | -4.03 (2.66) | -3.92 [-4.68, -2.36] | -10.74 to 1.80 | 2 |
| Go | N2 | PSU | Notification | 17 | -4.29 (2.44) | -3.80 [-4.94, -2.91] | -10.18 to 0.11 | 1 |
| Go | P3 | NPSU | Silence | 17 | 3.80 (2.26) | 3.93 [2.05, 5.07] | -0.15 to 7.68 | 0 |
| Go | P3 | NPSU | Notification | 17 | 3.80 (2.48) | 3.67 [2.18, 4.89] | 0.37 to 8.34 | 0 |
| Go | P3 | PSU | Silence | 17 | 3.67 (2.39) | 2.99 [2.44, 5.17] | -0.90 to 8.77 | 0 |
| Go | P3 | PSU | Notification | 17 | 3.92 (2.62) | 3.68 [2.15, 4.76] | -1.09 to 9.56 | 1 |
| Go | LP | NPSU | Silence | 17 | 0.99 (0.98) | 1.16 [0.25, 1.84] | -0.49 to 2.51 | 0 |
| Go | LP | NPSU | Notification | 17 | 1.00 (1.16) | 0.89 [0.35, 1.62] | -1.08 to 3.23 | 0 |
| Go | LP | PSU | Silence | 17 | 1.46 (1.43) | 1.15 [0.22, 1.92] | 0.09 to 4.49 | 1 |
| Go | LP | PSU | Notification | 17 | 1.13 (1.20) | 1.25 [0.08, 1.57] | -0.41 to 3.76 | 0 |
| No-Go | N2 | NPSU | Silence | 17 | -3.99 (2.05) | -3.78 [-4.66, -3.41] | -8.28 to -0.32 | 4 |
| No-Go | N2 | NPSU | Notification | 17 | -3.69 (2.61) | -3.13 [-4.30, -2.61] | -10.56 to 0.85 | 3 |
| No-Go | N2 | PSU | Silence | 17 | -5.13 (2.41) | -4.67 [-6.91, -3.14] | -11.08 to -2.36 | 0 |
| No-Go | N2 | PSU | Notification | 17 | -5.07 (2.36) | -4.50 [-6.23, -3.35] | -10.61 to -2.27 | 1 |
| No-Go | P3 | NPSU | Silence | 17 | 5.99 (2.95) | 5.56 [3.69, 7.92] | 1.50 to 12.24 | 0 |
| No-Go | P3 | NPSU | Notification | 17 | 5.04 (2.70) | 4.80 [3.13, 6.57] | 1.55 to 10.19 | 0 |
| No-Go | P3 | PSU | Silence | 17 | 6.84 (3.50) | 6.14 [5.22, 8.31] | 1.82 to 14.64 | 2 |
| No-Go | P3 | PSU | Notification | 17 | 6.58 (3.53) | 6.75 [4.01, 9.23] | 0.05 to 11.84 | 0 |
| No-Go | LP | NPSU | Silence | 17 | 0.52 (0.90) | 0.53 [-0.14, 1.13] | -0.88 to 2.05 | 0 |
| No-Go | LP | NPSU | Notification | 17 | 0.90 (1.02) | 0.69 [0.15, 1.40] | -0.49 to 3.00 | 0 |
| No-Go | LP | PSU | Silence | 17 | 1.28 (1.17) | 1.23 [0.55, 2.43] | -1.43 to 3.25 | 0 |
| No-Go | LP | PSU | Notification | 17 | 0.83 (1.05) | 0.59 [0.25, 1.19] | -1.06 to 3.09 | 2 |
S5.2. Assessment of statistical assumptions
Shapiro–Wilk tests assessed residual normality in the models of participant-level mean amplitudes across blocks (between-subject model) and Notification minus Silence differences (within-subject model). Brown–Forsythe tests assessed equality of variances between groups for the corresponding participant-level means and differences. With two repeated-measures levels, sphericity is automatically satisfied.
| Trial | Component | Shapiro (between) | Brown–Forsythe (between) | Shapiro (within) | Brown–Forsythe (change) |
|---|---|---|---|---|---|
| Go | N2 | .422 | .685 | .013 | .443 |
| Go | P3 | .566 | .756 | .090 | .860 |
| Go | LP | .314 | .662 | .183 | .232 |
| No-Go | N2 | .083 | .668 | .547 | .657 |
| No-Go | P3 | .304 | .366 | .553 | .432 |
| No-Go | LP | .388 | .879 | .496 | .450 |
The only nominally significant assumption test was the Shapiro–Wilk test for the Go N2 within-subject model (p = .013). No Brown–Forsythe test reached the nominal .05 threshold. For No-Go LP, none of the assumption tests reached this threshold. Non-significant diagnostic tests do not establish that assumptions hold exactly.
Go trials
No-Go trials
S5.3. Individual amplitude distributions in Go trials
Individual participant amplitudes and boxplots complement the Go waveform figures. Points represent participant-level ROI mean amplitudes; boxes show the median and interquartile range, and whiskers extend to the most extreme observations within 1.5 times the interquartile range. No observations were excluded on the basis of this descriptive criterion.
S5.4. Complementary nonparametric analyses
Following the analysis script, rank-based tests were triggered by nominally significant Shapiro–Wilk tests. For the Go N2 within-subject model, a paired Wilcoxon signed-rank test compared blocks across participants and a Mann–Whitney test compared participant-level Notification minus Silence differences between groups. These tests are complementary rather than exact nonparametric equivalents of the factorial ANOVA. Reported p-values are unadjusted.
| Trial | Component | Effect | Test | Statistic | p |
|---|---|---|---|---|---|
| Go | N2 | Block | Paired Wilcoxon | 199 | .094 |
| Go | N2 | Group × Block | Mann-Whitney on change | 141 | .918 |
Neither test reached the nominal .05 significance threshold.
The ERP ANOVA p values were adjusted across the three components separately for each trial type and effect. Post hoc tests were triggered by an unadjusted interaction p value below .05 and adjusted across four contrasts. As reported in the main manuscript, the No-Go LP interaction survived the component-wise correction, whereas none of its four follow-up contrasts survived their corresponding correction. Thus, the omnibus interaction does not establish a significant simple effect within a particular group or block.
S6. Supplementary temporal principal component analysis
Temporal principal component analysis (PCA) was used to assess whether late activity was distinguishable from the preceding P3 in time. Separate covariance-based PCAs were conducted for Go and No-Go trials using participant-by-block-by-electrode waveforms (2,176 observations per trial type; 128 time points). Parallel analysis retained six factors for Go and five for No-Go, followed by Promax rotation (κ = 3). Factor scores were averaged across the LP ROI (CP1, Cz, CP2 and Pz). The Group × Block interaction was evaluated by comparing participant-level Notification minus Silence score differences between groups using an independent-samples Student’s t test (F = t²). To complement the main manuscript, Supplementary Table 9 reports the peak latency, percentage of variance, and Group × Block interaction test for every retained factor, including those not identified as P3 or late positivity (LP).
| Trial | Factor | Component | Peak (ms) | Variance (%) | F | p | Adjusted p |
|---|---|---|---|---|---|---|---|
| Go | 1 | — | 265.62 | 32.09 | 0.17 | .679 | 1.000 |
| Go | 2 | LP | 687.50 | 16.00 | 1.13 | .295 | 1.000 |
| Go | 3 | — | 492.19 | 9.00 | 1.31 | .261 | 1.000 |
| Go | 4 | — | 218.75 | 5.04 | 5.50 | .025 | .152 |
| Go | 5 | P3 | 375.00 | 16.59 | 0.03 | .873 | 1.000 |
| Go | 6 | — | 187.50 | 3.89 | 1.33 | .258 | 1.000 |
| No-Go | 1 | P3 | 367.19 | 33.11 | 0.93 | .343 | 1.000 |
| No-Go | 2 | — | 273.44 | 20.40 | 0.80 | .379 | 1.000 |
| No-Go | 3 | — | 484.38 | 9.72 | 0.41 | .527 | 1.000 |
| No-Go | 4 | LP | 679.69 | 13.24 | 8.44 | .007 | .033 |
| No-Go | 5 | — | 210.94 | 4.94 | 0.02 | .887 | 1.000 |
Because Promax is an oblique rotation, the reported factor-specific variance percentages are presented individually rather than interpreted as independent, additive shares of variance. The No-Go LP factor (factor 4; peak latency = 679.69 ms) was the only retained factor with a Group × Block interaction that reached significance after Bonferroni adjustment (F(1, 32) = 8.44, adjusted p = .033). The Go factor 4 interaction reached nominal significance (p = .025) but did not survive adjustment (adjusted p = .152). No other factor reached the nominal .05 threshold.
S7. Exploratory factorial mass univariate analysis
S7.1. Rationale and analytical procedure
A factorial mass univariate analysis (FMUT) was performed as an exploratory complement to the ROI-based analyses to examine experimental effects across all electrodes and time points. Unlike the ROI-based ANOVA, the whole-epoch analysis does not require the a priori selection of electrode sites or time windows, allowing the detection of effects that may extend beyond the hypothesized regions, potentially at the cost of lower sensitivity to focal effects.
Separate 2 × 2 mixed factorial analyses (Group: NPSU vs. PSU; Block: Notification vs. Silence) were conducted for Go and No-Go trials using cluster-mass permutation testing implemented in FMUT. Each analysis included 34 participants (17 per group), 32 electrodes, 10,000 permutations, a channel-neighborhood parameter (chan_hood) of 80, and a significance threshold of .05. The whole-epoch analysis covered 0–789 ms (102 time points). Additional exploratory analyses restricted the temporal search space to N2 (200–350 ms), P3 (250–500 ms), and LP (600–789 ms), retaining all electrodes. The actual sampled windows reported by the software were approximately 203–352, 250–500, and 602–789 ms, respectively. The cluster-level p values account for the electrode-by-time search within each analysis and effect; no further adjustment across trial types, effects or temporal searches was applied in this report. The temporal-window analyses were additional exploratory searches and used broader N2 and P3 windows than the ROI amplitude analyses.
S7.2. Whole-epoch results
| Trial | Effect | Cluster | Cluster mass | Cluster p |
|---|---|---|---|---|
| Go | Group | 5 | 407.11 | 0.2757 |
| Go | Block | 2 | 245.10 | 0.3787 |
| Go | Group × Block | 6 | 157.54 | 0.6181 |
| No-Go | Group | 22 | 2097.42 | 0.0117 |
| No-Go | Block | 15 | 392.68 | 0.1717 |
| No-Go | Group × Block | 28 | 361.75 | 0.1882 |
The analysis of No-Go trials revealed a significant main effect of Group (cluster mass = 2097.42, p = .0117), spanning approximately 570–789 ms and 22 electrodes. Within this cluster, amplitudes were more positive in the PSU than in the NPSU group over frontal, central and temporal sites and more negative over centro-parietal and parieto-occipital sites (PO9, O1, Oz, O2, PO10, P8, P4, CP6), according to the directional description of the original analysis. The directional description refers to the underlying voltage differences, rather than the unsigned F statistics shown in the raster. This spatially distributed pattern should be distinguished from the main effect of Group in the centroparietal LP ROI, which was not significant in the ROI-based ANOVA. The cluster test does not establish a difference in normalized scalp topography or significance at individual electrodes.
No significant clusters were found for Block (minimum cluster p = .1717) or Group × Block. The interaction cluster with the lowest p value (656–727 ms; Cz, CP1, Pz, P4, CP2, CP6, C4, FC2; cluster mass = 361.75, p = .1882) overlapped in time and electrode coverage with the LP interaction but did not survive correction over the whole epoch. For Go trials, no significant clusters were found (all p ≥ .2757).
S7.3. Exploratory time-window analyses
| Trial | Window | Group | Block | Group × Block |
|---|---|---|---|---|
| Go | N2 | 0.1505 | 0.9497 | 0.1877 |
| Go | P3 | 0.2128 | 0.7843 | 0.4891 |
| Go | LP | 0.2506 | 0.7216 | 0.3157 |
| No-Go | N2 | 0.1114 | 0.5499 | 0.7889 |
| No-Go | P3 | 0.2199 | 0.1553 | 0.7062 |
| No-Go | LP | 0.0061 | 0.0369 | 0.0396 |
No clusters reached the within-analysis threshold of .05 in the N2 or P3 windows for either trial type, or in the Go LP window. In the No-Go LP window, three clusters reached this threshold: Group (mass = 1953.83, p = .0061; 602–789 ms; 22 electrodes), Block (mass = 392.68, p = .0369; 688–789 ms; nine electrodes: P3, P7, PO9, O1, Oz, O2, PO10, P8, P4), and Group × Block (mass = 361.75, p = .0396; 656–727 ms; eight electrodes listed above).
S7.4. Relation to the ROI-based findings
The No-Go interaction cluster overlapped the LP measurement window and included all four LP ROI electrodes. Its mass and reported temporal extent were unchanged when the search was restricted to the LP window, but its cluster-level p value differed (.0396 vs. .1882 for the whole epoch). This is compatible with a difference in sensitivity associated with restricting the temporal search space. The whole-epoch analysis did not provide statistically significant evidence of a Group × Block interaction. The restricted-window result must be interpreted in light of the additional exploratory searches and is not independent confirmation of the ROI result, because the same recordings were analyzed. Neither the difference in p values nor the cluster boundaries establishes that the underlying effect is focal or determines its precise onset, offset, or electrode-specific significance.