A cabinet filter free-area worksheet in R

The grille opening controls the area available for airflow. Record the clear opening and the grille open-area fraction before comparing replacement fans.

The calculation below uses illustrative dimensions. Use the measured airflow and the grille drawing for a real enclosure, and compare candidate fan curves at the expected system pressure.

Use the Hongbo Motor industrial cooling fan catalog to identify candidate fan families and request part-specific performance data.

This procurement resource was prepared for Hongbo Motor.

Calculate the open area

width_m <- 0.12
height_m <- 0.12
open_fraction <- 0.65
airflow_m3_h <- 80
free_area_m2 <- width_m * height_m * open_fraction
air_velocity_m_s <- (airflow_m3_h / 3600) / free_area_m2
round(c(free_area_m2 = free_area_m2, air_velocity_m_s = air_velocity_m_s), 3)

The example yields 0.00936 m² of open area and about 2.37 m/s of face velocity. Select the fan using its pressure–airflow curve and the actual filter and grille.