1 Site Document for Edmonton Woodcroft Air Monitoring Station

1.1 Station Map

1.2 General Station Information

Station
Station Information
Station number 01CAP (14C)
Station Name Edmonton Woodcroft
Date station established Jun 01, 2013 (Industry); August 1, 2022 (ACA)
Date information last updated 01-Jun-25
General Description The Edmonton Woodcroft station is located in the Woodcroft Community League building, situated within Coronation Park (north side). The Station is located near residential and commercial property. The station is situated inside the buidling.
Station address 13924 115 Avenue NW, Edmonton, AB
Station Location 12-12-53-25 W4M
Latitude 53.56466
Longitude -113.562667
UTM 12U 330287E 5938142N
Elevation 675m
Airshed Alberta Capital Airshed, ACA
Nearest street 115 Ave NW
Community City of Edmonton
Population 981280
Census Year 2017
Land Use
Scale of representativeness, 500m
Land use by sector North residential
Land use by sector East residential
Land use by sector South park
Land use by sector West park / commercial
Angle of elevation to nearby buildings intake is on top of building
Average building height in the area (m) 6m
Air flow restrictions from North potential trees
Air flow restrictions from South no
Air flow restrictions from East no
Air flow restrictions from West no
Distance to nearest trees 34m
Height of trees 8m
Manifold Type glass / stainless steel intake
Manifold height above structure 2m
Meterological Equipment type Crank down tower with RM-Young
Meterological Equipment height 10m
Meterological Equipment distance from station tied to building

1.3 Owner / Operator

Owner/Operator/Approval Holder
Station Information
Operator Alberta Capital Airshed, ACA
Address 8737 53 Avenue NW, Edmonton, AB T6E 5E9
Contact Gary Redmond
Phone number 587.520.7935
email
Name of owner/approval holder Alberta Capital Airshed, ACA
Address
Contact name
Phone number
email address
Approval number

1.4 Map of Site Influences

Localized sources (within 100 metres of station)
Description Distance (m) Angle (from N) Height (m)
tree 34 107deg 7
tree 38 240deg 6
tree 42 2deg 14
road 104 66deg 0
tree 68 280deg 14
parking lot 46 191deg 0
Roadway influences
Road Type Traffic Volume Distance Description
115 Ave NW Paved unknown 65m north residential
142 St NW Paved unknown 208m west commuting road
Major point sources
Source Name Source Type Distance from Site (km) Compass Direction
refer to map commerical <1km surrounding station
refer to map residential <1km surrounding station

1.5 Monitoring Equipment

Station Instruments
Instrument Type Make Model Serial Number AMU Date Installed
Nitrogen Oxides (NO-NO2-NOx) Thermo Scientific 42iQ 1201677915 2022
Sulphur Dioxide (SO2) Thermo Scientific 43iQ 12228021053 2022
Ozone (O3) Thermo Scientific 49i 1227254859 AMU # 2012
PM2.5 R&P TEOM 1400AB/FDMS 140AB241510206 2006
Dilution Calibrator SABIO 2010 2022
Zero-Air Generator API Teledyne N701 2022
NAPS PM Sampler PM2.5 R&P 2005 2000B20672-0205 2005
NAPS PM Sampler PM10 R&P 2005 2000B20669-0205 2005
NAPS PM Sampler TSP R&P 2005 2000B20670-0205 2005
Wind RM Young 05305VK 50541 2015
Wind Tower Aluma 2010
Temperature/Relative Humidity Campbell Scienitifc HMP 45C 2015
Station Temperature Campbell Scienitifc 2010
Data Logger Campbell Scienitifc CR3000 3488 2015
Cellular Modem Sierra Wireless LS300 2015
Battery Back-up APC 1500VA 2018
HVAC NOMA Portable AC N/A N/A 2021
Station N/A N/A N/A N/A

1.6 Site Plan view and Cross sectional analysis

1.6.1 Illustration of distance and height requirements

Plan view
Plan view


Plan view One
a = height of sample inlet above ground
b = distance from sample inlet to any air flow obstacle (eg buildings) must be greater than 2 times the height of the obstacle above the sample inlet
c = sample inlet must be greater than 20 metres horizontally from trees

Description Distance (m) Angle (from N) Height (m) b Angle >26.5 deg >2 x b >20m trees
station inlet 0 7.5 NA NA
tree 34 107deg 7.0 3 5.0 pass pass
tree 38 240deg 6.0 2 3.0 pass pass
tree 42 2deg 14.0 10 13.4 pass pass
road 104 66deg 0.0 NA NA pass
tree 68 280deg 14.0 10 8.4 pass pass
parking lot 46 191deg 0.0 NA NA pass

1.6.2 Illustration of distance and height requirements

Plan view Two
h1 = height of obstacle 1; h2 = height of obstacle 2
d = must be greater than 2.5 times the shelter height (minimum of 10 metres)
e = height above any obstacle greater than 2 metres
f = distance must be minimum 10 times h1; g = distance must be minimum 10 times h2

Description Distance (m) d > 10m structure >10x height trees >10x height
station inlet 0
tree 34 pass fail
tree 38 pass fail
tree 42 fail fail
road 104 pass
tree 68 fail fail
parking lot 46 pass

1.7 Photographs for Continuous Stations

1.7.1 Station Pictures

\label{fig:fig}Station looking East

Station looking East


\label{fig:fig}Station looking North

Station looking North


\label{fig:fig3}Station looking South

Station looking South


\label{fig:figs}Station looking West

Station looking West


\label{fig:figs}Sample Inlet 1

Sample Inlet 1


\label{fig:figs}Station Equipment Rack

Station Equipment Rack


\label{fig:figs}Station Manifold

Station Manifold


\label{fig:figs}Station Particulate Analyzer

Station Particulate Analyzer

1.9 Network of Stations and Region