Viable C. estertheticum cell counts on stainless steel coupons with and without UV-C treatment1,2,3,4 | ||||||
No. of cells (log CFU/cm²)
|
||||||
---|---|---|---|---|---|---|
Temperature Treatment |
UV-C Treatment
|
No Treatment
|
||||
Day 0 | Day 2 | Day 4 | Day 0 | Day 2 | Day 4 | |
80°C | 0.88 | ND | ND | 1.72 | 1.48 | 1.48 |
Room Temperature | ND | 1.33±0.15 A | ND | 1.15±1.15 A | 2.71±0.16 A | 2.53±0.31 A |
1 Values are expressed as means ± standard deviations. Values with different uppercase letters in each row are significantly different (P < 0.05). | ||||||
2 Detection limit: 1.18 log CFU/cm2. | ||||||
3 ND, not detected. | ||||||
4 The values for the 80°C group represent one data replicate, while the values for the Room Temperature group represent two data replicates. |