Field | Protocol | Left | Right | All |
---|---|---|---|---|
1.5T | P01 | 0.892 | 0.899 | 0.899 |
P02 | 0.898 | 0.902 | 0.905 | |
P03 | 0.731 | 0.864 | 0.807 | |
P04 | 0.801 | 0.877 | 0.848 | |
P05 | 0.736 | 0.812 | 0.784 | |
P06 | 0.853 | 0.898 | 0.885 | |
P07 | 0.720 | 0.777 | 0.750 | |
P08 | 0.758 | 0.815 | 0.795 | |
P09 | 0.623 | 0.723 | 0.682 | |
P10 | 0.610 | 0.649 | 0.632 | |
3.0T | P01 | 0.876 | 0.903 | 0.894 |
P02 | 0.859 | 0.888 | 0.877 | |
P03 | 0.476 | 0.601 | 0.554 | |
P04 | 0.480 | 0.672 | 0.595 | |
P05 | 0.279 | 0.420 | 0.360 | |
P06 | 0.246 | 0.390 | 0.328 | |
P07 | 0.392 | 0.604 | 0.524 | |
P08 | 0.356 | 0.533 | 0.460 | |
P09 | 0.607 | 0.785 | 0.708 | |
P10 | 0.303 | 0.423 | 0.380 |
Multicenter Test-Retest and Acquisition Protocol Reproducibility of Liver Iron Quantification - Correlation with Ferriscan-LIC
LIC vs R2*
The R-sqr of linear fit between LIC and R2* are tabulated in Table 1 below by field strength and protocol (left/right lobe and overall). P01 & P02 generally have better fit than the rest.