| Station | Information |
|---|---|
| Station number | 12AQM (18C) |
| Station Name | Edmonton East |
| Date station established | Jan 01, 1998 (AEPA); April 1, 2023 (ACA) |
| Date information last updated | 25-Mar-24 |
| General Description | The Edmonton East station is located in Strathcona County just east of the City of Edmonton boundary. The Station is located near petrochemical refineries and commercial areas. The station is situated on a gravel pad surrounded by a fence and industrial area. |
| Station address | 10503 17 Street NW, Sherwood Park, AB |
| Station Location | 5-5-53-23 W4M |
| Latitude | 53.548008 |
| Longitude | -113.367969 |
| UTM | 12U 343113E 5935843N |
| Elevation | 672m |
| Airshed | Alberta Capital Airshed, ACA |
| Nearest street | 17Street NW |
| Community | Sherwood Park County |
| Population | 72017 |
| Census Year | 2021 |
| Land Use | |
| Scale of representativeness, | 500m |
| Land use by sector North | industrial |
| Land use by sector East | industrial |
| Land use by sector South | industrial |
| Land use by sector West | industrial |
| Angle of elevation to nearby buildings | Greatest Angle = 2.5 degrees, from 143deg |
| Average building height in the area (m) | 5m |
| Air flow restrictions from North | potential trees |
| Air flow restrictions from South | building |
| Air flow restrictions from East | no |
| Air flow restrictions from West | no |
| Distance to nearest trees | 20m |
| Height of trees | 11m |
| Manifold Type | glass / stainless steel intake |
| Manifold height above structure | 2m |
| Meterological Equipment type | Crank down tower with RM-Young |
| Meterological Equipment height | 10m |
| Meterological Equipment distance from station | tied to station end |
| Station | Information |
|---|---|
| Operator | Alberta Capital Airshed, ACA |
| Address | 8737 53 Avenue NW, Edmonton, AB T6E 5E9 |
| Contact | Gary Redmond |
| Phone number | 587.520.7935 |
| gredmond@capitalairshed.ca | |
| Name of owner/approval holder | Alberta Environment and Protected Areas, AEPA |
| Address | 1200 10423 - 101 Street NW Edmonton AB T5H 0E9 |
| Contact name | Marty Collins |
| Phone number | 780.427.2711 |
| email address | marty.collins@gov.ab.ca |
| Approval number |
| Description | Distance (m) | Angle (from N) | Height (m) |
|---|---|---|---|
| building | 24 | 143deg | 5 |
| road | 88 | 268deg | 0 |
| tree | 20 | 329deg | 9 |
| tree | 39 | 77deg | 11 |
| tree | 63 | 102deg | 12 |
| railroad | 96 | 89deg | 0 |
| Road | Type | Traffic Volume | Distance | Description |
|---|---|---|---|---|
| 17Street NW | Paved | unknown | 88m west | industrial |
| railway | Rail | unknown | 63m east-southeast | rail |
| Source Name | Source Type | Distance from Site (km) | Compass Direction |
|---|---|---|---|
| refer to map | oil and gas | <1km | surrounding station |
| refer to map | industrial | <1km | surrounding station |
| Instrument Type | Make | Model | Serial Number | AMU | Date Installed |
|---|---|---|---|---|---|
| Nitrogen Oxides (NO-NO2-NOx) | Thermo Scientific | 42iQ | 1200196027 | AMU # | 2020 |
| Sulphur Dioxide (SO2) | Thermo Scientific | 43iQ | 12100510376 | AMU # | 2021 |
| Ozone (O3) | Thermo Scientific | 49iQ | 1202959581 | AMU # | 2020 |
| Carbon Monoxide (CO) | Thermo Scientific | 48i-TLE | 1408761374 | AMU # | 2014 |
| Hydrogen Sulphide (H2S) | Thermo Scientific | 450i | 1180030040 | AMU # | 2018 |
| Hydrocarbon’s (CH4/NMHC) | Thermo Scientific | 55i | 1180030035 | AMU # | 2018 |
| Particulate Matter (PM2.5) | API Teledyne | T640 | 1165 | AMU # 2360 | 2021 |
| Dilution Calibrator | Thermo Scientific | 146iQ | AMU # | 2023 | |
| Zero-Air Generator | API Teledyne | T701 | AMU # | ||
| Hydrogen Generator | VICI | AMU # | |||
| NAPS VOC Sampler | AMU # | ||||
| Wind | RM Young | 05305-10 | |||
| Wind Tower | Aluma | 2022 | |||
| Temperature/Relative Humidity | Campbell Scienitifc | ||||
| Station Temperature | Comet | ||||
| Data Logger | Campbell Scienitifc | CR1000X | 2023 | ||
| Cellular Modem | Microhard | iPN4G | AMU # 2315 | 2023 | |
| Battery Back-up (x2) | Tripp-Lite | 2023 | |||
| HVAC (AC with heat pump) | BARD | 2022 | |||
| Station | National Trailer | (10x20) w/ Stairs | 2022 |
a
= height of sample inlet above ground
b = distance from sample
inlet to any air flow obstacle (eg buildings) must be greater than 2
times the height of the obstacle above the sample inlet
c = sample
inlet must be greater than 20 metres horizontally from trees
| Description | Distance (m) | Angle (from N) | Height (m) | b | Angle | >26.5 deg | >2 x b | >20m trees |
|---|---|---|---|---|---|---|---|---|
| station inlet | 0 | 4 | NA | NA | ||||
| building | 24 | 143deg | 5 | 1 | 2.4 | pass | pass | pass |
| road | 88 | 268deg | 0 | NA | NA | pass | ||
| tree | 20 | 329deg | 9 | 5 | 14.0 | pass | pass | |
| tree | 39 | 77deg | 11 | 7 | 10.2 | pass | pass | |
| tree | 63 | 102deg | 12 | 8 | 7.2 | pass | pass | |
| railroad | 96 | 89deg | 0 | NA | NA | pass |
h1
= height of obstacle 1; h2 = height of obstacle 2
d = must be
greater than 2.5 times the shelter height (minimum of 10 metres)
e
= height above any obstacle greater than 2 metres
f = distance must
be minimum 10 times h1; g = distance must be minimum 10 times h2
| Description | Distance (m) | d > 10m | structure >10x height | trees >10x height |
|---|---|---|---|---|
| station inlet | 0 | |||
| building | 24 | pass | fail | |
| road | 88 | pass | ||
| tree | 20 | fail | fail | |
| tree | 39 | fail | fail | |
| tree | 63 | fail | fail | |
| railroad | 96 |
Station looking East
Station looking North
Station looking South
Station looking West
Sample Inlet 1
Sample Inlet 2
Station Equipment Rack
Station Manifold
Station Particulate Analyzer
Station Particulate Manifold