Heterogeneity Quantification Using Dykstra-Parson and Lorenze Cofficient Methods
Fatima Jalil Sajet 2023/12/16
Heterogeneity is a function of horizontal permeability, and can be quantified by two techniques:
1- Dykstra-Parsons
2- Lorenz Coefficient
The data-set used:
data = read.csv(“karpur.csv”)
head(data)
1- Dykstra-Parsons This method required using only the K.core column from our data-set.
Here I am sorting the whole data-set descending based on K.core than spliting cored permeability as an individual vector:
#SORTING BASED ON K CORE
data = data[order(data\(k.core, decreasing = TRUE), ] K = data\)k.core Next creating another vector containing the number of samples ≥ k, while the order of data is descending the 1st K will has only one permeability greater or equals to its value while the last K has 819 (data length) of permeability values greater or equals to its value.
sample = c(1:819) The next parameter required is the percent of samples that have permeability greater or equal to the current K value, which represent the probability of current K value. note: the division on [length of the data-set +1] to neglect having probability of zero and one.
k_percent = (sample * 100) / 820
Now, all parameters is ready to use. Let’s plot Y values (logarithmic permeability) and X values (probability):
x lab = “Portion of Total Sample Having Higher K” y lab = “Permeability (md)” p lot(k_percent, K, log = ‘y’, x lab = x lab, y lab = y lab, pch = 10, cex = 0.5, col = “#001c49”)
Now, let’s find the Linear Model that fits the data, lm() function used to build linear regression model:
log_k = log(K) model = lm(log_k ~ k_percent) plot(k_percent,log_k, xlab = xlab, ylab = ylab, pch = 10, cex = 0.5, col = “#001c49”) abline(model, col = ‘red’, lwd = 2)
summary(model) ## ## Call: ## lm(formula = log_k ~ k_percent) ## ##
Residuals: ## Min 1Q Median 3Q Max ## -5.8697 -0.2047 0.1235 0.3150
0.4280 ## ## Coefficients: ## Estimate Std. Error t value
Pr(>|t|)
## (Intercept) 9.2584172 0.0377994 244.94 <2e-16 ##
k_percent -0.0426137 0.0006549 -65.07 <2e-16 ## — ##
Signif. codes: 0 ‘’ 0.001 ’’ 0.01 ’’ 0.05 ‘.’
0.1 ’ ’ 1 ## ## Residual standard error: 0.5404 on 817 degrees of
freedom ## Multiple R-squared: 0.8382, Adjusted R-squared: 0.838 ##
F-statistic: 4234 on 1 and 817 DF, p-value: < 2.2e-16
Our model has good R2 value which is obvious from the plot. abline is just adding the fitted line.
Now let’s find K values at K50 & K84.1 , by define new data frame that contains the required values:
new_data = data.frame(k_percent = c(50, 84.1)) Now using predict () function to predict from given model:
predicted_values = predict(model, new_data) so the logarithmic permeability of K50 = 7.13 & K84.1 = 5.67
to calculate heterogeneity index
V= K50-K84.1/K50
heterogenity_index = (predicted_values[1] - predicted_values[2]) / predicted_values[1]
heterogenity_index ## 1 ## 0.2038692 So, the heterogeneity index = 0.204 , which indicate slightly heterogeneous class of permeability distribution, the low value of heterogeneity allow to use homogeneous model with minimum error.
2- Lorenz Coefficient This method is measuring the inequality of distribution of a property, in finance for example: Is the income distributed equally among the population? The same concept can be applied in reservoir engineering but between the flow capacity (KH) and storage volume (PHIK).
Using the same data:
data = read.csv(“karpur.csv”) Then, we need to calculate the thickness of each permeability based on Depth[i] - Depth[i-1] , then update the data by sorting it based on Permeability.core:
thickness calculation
thickness = c(0.5) for (i in 2:819) { h = data\(depth[i] - data\)depth[i-1] thickness = append(thickness, h) }
data = data[order(data$k.core, decreasing = TRUE), ] Then, calculate the flow capacity and storage capacity which is easily the multiplication between permeability and porosity with corresponding thickness. Then calculate the cumulative sum of each one using cumsum() function.
KH = thickness * data\(k.core PH = thickness * data\)phi.core cum_sum_kh = cumsum(KH) cum_sum_ph = cumsum(PH) Finally we need to calculate the following terms:
∑cum.k.coretotal & ∑cum.phi.coretotal
frac_tot_vol = (cum_sum_ph/100) / max(cum_sum_ph/100) #to convert phi between (0,1) frac_tot_flow = cum_sum_kh / max(cum_sum_kh) Now, plotting the percent of storage capacity on X-axis and the percent of flow capacity on Y-axis:
plot(frac_tot_vol,frac_tot_flow, pch = 10, cex = 0.2, col = ‘#001c49’, text(0.4, 0.8, “D”)) text(0,0, “A”, pos = 2) text(1,1, “B”, pos = 1) text(1,0, “C”, pos = 2) abline(0,1, col = ‘red’, lwd = 2)
Now, We need to estimate the area under the curve (ADBCA).
using AUC() function that approximate the area under a curve, trapezoid the numerical technique that used:
require(“DescTools”) ## Loading required package: DescTools ## Warning: package ‘DescTools’ was built under R version 4.2.2 library(DescTools)
area = AUC(frac_tot_vol, frac_tot_flow, method=“trapezoid”) The formula of Lorenz Coefficient:
Lorenz coficient=(Area ADBA)/ABCD
Area ADBA, is just area value - 0.5:
Lcoff = (area - 0.5) / 0.5 The heterogeneity Index:
Lcoff ## [1] 0.4524741 is 0.45 , in Lorenz method if the value is closer to zero, it considers more heterogeneous. So the current value considers as heterogeneous or high heterogeneous reservoir